Mercurial > hg > ltpda
view m-toolbox/m/gui/gltpda/g_iplot.m @ 51:9d5c88356247 database-connection-manager
Make unit tests database connection parameters configurable
author | Daniele Nicolodi <nicolodi@science.unitn.it> |
---|---|
date | Wed, 07 Dec 2011 17:24:37 +0100 |
parents | f0afece42f48 |
children |
line wrap: on
line source
function g_iplot(block) % This is the automatic function wrapper % ================================================================= % ================ level-2 M file S-function ====================== % ================================================================= % To save as standalone variable(s) into global shared workspace the AO(s) % received as input from the corresponding block, executed in Simulink. % % $Id: g_iplot.m,v 1.1 2008/03/01 13:43:20 nicola Exp $ setup(block); %% function setup(block) global LTPDAinvar; %% Register dialog parameter: none, because they're retrieved directly %% from the memory. This will prevent the user to modify the parameters %% outside the proper parameters panel: block.NumDialogPrms = 0; %% Register number of input and output ports block.NumInputPorts = 1; block.NumOutputPorts = 1; %% Setup functional port properties to dynamically inherited. block.SetPreCompInpPortInfoToDynamic; block.SetPreCompOutPortInfoToDynamic; block.InputPort(1).DirectFeedthrough = true; block.InputPort(1).DatatypeID = 0; block.InputPort(1).Complexity = 0; % block.InputPort(1).Dimensions = 2; block.OutputPort(1).DatatypeID = 0; block.OutputPort(1).Complexity = 0; % block.OutputPort(1).Dimensions = 1; block.SampleTimes = [0 0]; block.SetAccelRunOnTLC(false); %% Register methods block.RegBlockMethod('SetInputPortSamplingMode',@SetInpPortFrameData); block.RegBlockMethod('SetInputPortDimensions', @SetInpPortDims); block.RegBlockMethod('SetOutputPortDimensions', @SetOutPortDims); block.RegBlockMethod('Outputs', @Outputs); function SetInpPortFrameData(block, idx, fd) block.InputPort(1).SamplingMode = fd; block.OutputPort(1).SamplingMode = fd; function SetInpPortDims(block, idx, di) block.InputPort(idx).Dimensions = di; function SetOutPortDims(block, idx, di) block.OutputPort(idx).Dimensions = di; %% function Outputs(block) global LTPDAinvar % figure hold on switch length(block.InputPort(1).Data) case 1 iplot(LTPDAinvar{block.InputPort(1).Data}); case 2 iplot(LTPDAinvar{block.InputPort(1).Data(1)},LTPDAinvar{block.InputPort(1).Data(2)}); case 3 iplot(LTPDAinvar{block.InputPort(1).Data(1)},LTPDAinvar{block.InputPort(1).Data(2)},LTPDAinvar{block.InputPort(1).Data(3)}); case 4 iplot(LTPDAinvar{block.InputPort(1).Data(1)},LTPDAinvar{block.InputPort(1).Data(2)},LTPDAinvar{block.InputPort(1).Data(3)},LTPDAinvar{block.InputPort(1).Data(4)}); end % %======================================================================== block.OutputPort(1).Data = block.InputPort(1).Data; %endfunction